Mechanics

Number of test probes 4 (2 front/2 back) High speed Z-Axis probes with soft touch (requires soft touch probes)
Test probe pressure 2 -10 g
Number of CCD-cameras 2 (1 front/1 back) Fully automatic camera alignment for easy and fast compensation of board registration
Max test area (x/y) 28.7” x 24.8” 730mm x 630mm
Min board size (x/y) 2” x 2” 50mm x 50mm
Max board thickness 320mil 8mm
Min board thickness (standard) 5mil 0,12μm
Repeatable accuracy +/- 0.3mil 7,5μm
Resolution (x/y) +/- 0.3mil 7,5μm
Smallest testable pad size 2mil 50μm
Smallest testable distance/pitch 3mil 75μm
Board Loading Stretch/ Quick Frame

Electronics

Test voltage 20 V up to 1000 V (adjustable)
Test current 5 mA up to 500 mA (adjustable)
Continuity test 1 Ω up to 5000 Ω (dependent on the current, smaller current = larger resistance)
Isolation test 1 M Ω up to 500 M Ω

Software

Operating Software Windows 10 (English Version)
User Interface Gardien FPX with multi Language support (Chinese, Japanese, Spanish)
Data input formats

MNF1, MNF2, IPC 356A/B, EMMA

Test Floor Integration IT based communication and data exchange between Universal Grid, Flying Probe and Fault verification SW

Options

Hardware  
Vacuum plate: Single Sided for Flex / Thin core / Inner layer (min Board thickness 3mil/80μm)
Features  
Embedded resistor test  
Embedded capacitor test  
Software  
Data preparation software (Certified Ucamco)  
Verification software (Certified Ucamco)  
Test Floor Integration (TFI) capability  

Dimensions & Environmental conditions

Width 86.6" 2200mm
Depth 38.5" 980mm
Height 76" 1940mm
(without light)
  84.4" 2155mm (with light)
Weight 2866lbs 1300kg
Air humidity 45-65% - not condensing
Room temperature 64°-90 °F 18-32 °C
Power supply 230V, 50/60Hz, 1000W Single phase

Download the flyer here